RMS Values and AC Power
An AC voltage spends most of its time below its peak, so for heating it only counts as much as a steady , the root of the mean of its square. And only the part of the current that's in step with the voltage does any work on average, so .
What the symbols mean
- RMS voltage
The steady DC voltage that would heat a resistor at the same average rate. Outlets are rated in rms volts.
- Peak voltage
The amplitude of the sinusoid.
- Period
One full cycle, 1/f.
What the symbols mean
- Power factor
The fraction of the volt-amperes that does work: 1 for a heater, near 0 for a pure inductor or capacitor.
- RMS current
The peak current divided by √2, for a sinusoid.
What the symbols mean
- Impedance magnitude
Only the resistive part R of the impedance dissipates energy.
- Apparent power
Volts times amperes, in volt-amperes: what the wires and transformers must carry, whether or not it does work.
Explanation
An rms value is simply the steady DC value that would do the same heating as an AC wave. The name tells you how to compute it, read backwards: square the wave, take the mean, then take the root (root mean square). It's what lets a voltage that keeps flipping direction be called "120 V", and it's what you need to find real power. For a sine wave, : take (the peak) and scale it down by (because the wave spends most of its time below the peak). The power formula is plain volts times amps with one extra piece, (how in step the current is with the voltage). The square roots and cosines make it look worse than it is; it's really just an average plus a correction for timing.
What "120 volts" means. A 1500 W space heater plugged into a 120 V outlet sees a voltage that swings between V and V sixty times a second, passing through zero 120 times a second. So what does "120 V" refer to? It's the steady DC voltage that would heat the heater at the same average rate. Finding it is an average value problem.
RMS, derived. In a resistor, . Average it over one period using : the part averages to zero, leaving
So the effective voltage is the square root of the mean of . That's exactly the recipe in the name root mean square: . A 120 V outlet peaks at V, a 230 V outlet at 325 V. Currents work the same way, and AC meters read rms. The came from averaging , so for other waveforms you have to redo the integral: a square wave of height has , a triangle wave .
When current and voltage are out of step. In the last lesson we saw that inductors and capacitors shift the current's timing. So what does that do to power? Let and . The product-to-sum identity gives
The second term swings at twice the line frequency and averages to zero. It's energy flowing into an inductor's or capacitor's field and back out, twice per cycle. The first term is the steady part:
- A resistor has : all of its power is real.
- A pure inductor or capacitor has and . It borrows energy for a quarter cycle and returns it the next, for zero average power.
- In general , from the angle of in the phasors lesson, and since , the power is . Only resistance dissipates.
Why utilities care about power factor. If the back-and-forth part averages to zero, why worry about it? Because the wires still have to carry it. The product , the apparent power in volt-amperes, sets the current, and current is what heats cables and transformers ( losses) and what they must be sized for. A motor with power factor 0.7 draws 1.4 times the current of a heater with the same real power. The cure is power factor correction: a capacitor in parallel with the motor supplies the motor's back-and-forth current locally, so the line carries only the useful in-phase part.
The phasor shortcut. With rms phasors, , where is the complex conjugate. The conjugate subtracts the current's angle from the voltage's, leaving .
A common mistake. It's tempting to think power is always volts times amps, , because that's how it worked for DC. It isn't when there's a phase angle: that product is the apparent power, and the real power carries the extra . Also keep peak and rms values apart. Household ratings are rms, while the amplitude in is a peak. And check whether your calculator expects degrees or radians before taking that cosine.
See it
Worked examples
A 1500 W space heater runs on a 120 V (rms), 60 Hz outlet. Find its resistance, its rms and peak currents and the largest instantaneous power it draws.
- 1
A heater is a resistor, so gives Ω, and A.
A motor on a 240 V (rms), 60 Hz line acts as Ω in series with a reactance Ω. Find the current, power factor and real power. What capacitor across the motor brings the power factor to 1, and what current does the line carry then?
- 1
Ω, so A and . The real power is W; the apparent power is VA.
Practice
Type your answer and check it. Solve them all to complete the lesson.
Outlets in many countries supply 230 V rms. What is the peak voltage, in volts?
A sawtooth voltage ramps steadily from 0 to 6.0 V over each period, then drops instantly back to 0. Find the mean of over a period, in V², and the rms voltage, in volts.
A 50 V (rms) source at rad/s drives a 30 Ω resistor in series with a 25 μF capacitor. Find the average power delivered, in watts, and the power factor.
In AC steady state, what is the average power delivered to an ideal capacitor?
A 1200 W electric kettle runs on a 230 V (rms), 50 Hz supply. Find the peak current, in amperes, the peak instantaneous power, in watts, and the frequency at which the power pulses, in Hz.
The hand-crank generator from the Faraday's law lesson makes a 6.0 V peak EMF. Connected to a 12 Ω lamp (ignore the coil's own resistance and inductance), what average power does it deliver, in watts? By what factor does that power grow if you crank twice as fast?
A workshop's induction motor draws 20 A (rms) from a 240 V (rms), 60 Hz line at a power factor of 0.75, lagging. Find (a) the real power, in kW, (b) the capacitance, in μF, that connected in parallel raises the power factor to 1 and (c) the line current after correction, in amperes.
A load has V across it and draws A. Find the average power, in watts.
The hardest one here. Get it, and you've got this lesson.
A phone's wireless-charging receiver coil acts as a source: an induced EMF of 5.0 V rms at rad/s, in series with the coil's own impedance Ω (2.0 Ω of wire and a 20 μH inductance). You connect a load made of a capacitor in series with a resistor . Choose , in nF, and , in ohms, to deliver the most average power to , and find that power, in watts.
Where it's used
Power engineering runs on these formulas. Utilities bill large customers for a poor power factor and install capacitor banks at substations to correct it. Data centers size their power supplies in volt-amperes rather than watts, and an amplifier's rated output is an rms power. Wireless chargers and RFID readers use conjugate matching to push the most power across the gap. The 2ω pulsing of single-phase power is why large motors run on three-phase supplies, whose three pulsing powers add up to a constant.